Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev. osteoporos. metab. miner. (Internet) ; 8(2): 55-60, abr.-jun. 2016. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-154851

RESUMO

Introducción: Cada vez está más demostrado el papel de la vitamina D en múltiples patologías, una de ellas el desarrollo de un hiperparatiroidismo secundario al déficit de vitamina D. Los métodos de laboratorio de cuantificación de vitamina D en suero no estaban bien estandarizados hasta ahora, por lo que no podía establecerse con certeza a partir de qué niveles de vitamina D se producían determinadas anomalías como la elevación de la PTH. Nuestro estudio pretende determinar por debajo de qué niveles de vitamina D nos encontraremos con niveles de PTH anormalmente elevados, realizando la determinación de vitamina D en el laboratorio con una técnica debidamente estandarizada y fiable. Métodos: El estudio descriptivo y retrospectivo se realizó con pacientes mayores de 18 años en los que se hicieron simultáneamente determinaciones de PTH, 25(OH) vitamina D (25OHD) y que además tuvieran valores normales de calcio, filtrado glomerular y fósforo. Para la determinación de vitamina D se utilizó un método de electroquimioluminiscencia estandarizado con respecto a la técnica de gases-masas. Por el programa estadístico Stava versión 11 se calculó el valor de 25OHD para el que la PTH se elevaba por encima de 70 pg/ml con la mayor sensibilidad y especificidad. Resultados: Se incluyeron 4.083 pacientes, de los que 2.858 eran mujeres (70%) y 1.225 (30%) varones. La edad media de la población estudiada fue 60,60 años (desviación estándar, 15,29). El 74% de la población tenía una PTH en suero por debajo de 70 pg/ml (valores considerados normales) y el 26% mayor de 70 pg/ml. Al construir la curva de ROC de los niveles de 25OHD, en función de valores de PTH por debajo o por encima de 70 pg/ml, el área bajo la curva fue 0,5962 (p<0,0001). El punto de corte teniendo en cuenta conjuntamente la sensibilidad y la especificidad que determinaban los valores de vitamina D para predecir los valores de PTH por encima de 70 pg/ml fue 24 ng/ml. De los pacientes con PTH normal, el 71% tenían valores de vitamina D normales, mientras que, de los pacientes con PTH elevada (mayor de 70 pg/ml), casi la mitad presentaban una vitamina D menor de 24 ng/ml, porcentaje que aumentaba según se iba elevando la PTH. Conclusiones: El valor de 25OHD que muestra una mejor especificidad y sensibilidad para predecir valores anormalmente elevados de PTH es 24 ng/ml, valor superior al presentado en trabajos anteriores (alrededor de 18 ng/ml). Con los resultados de este estudio, realizado con un método debidamente calibrado, se puede decir que el 44,9% de pacientes con valores de vitamina D menores de 24 ng/ml presenta niveles de PTH anormalmente elevados, con una función renal normal y valores de calcio y fósforo normales. Este porcentaje es menor entre los 18 y 40 años (24%) y llega al 49% por encima de los 60 años. Estos pacientes podrían tratarse con vitamina D para evitar un posible hiperparatiroidismo secundario al déficit de dicha vitamina. Es importante tener en cuenta que el método de determinación de vitamina D utilizado debe estar debidamente estandarizado con respecto al método de gases-masas (AU)


Introduction: Vitamin D is increasingly recognized as playing a significant role in combatting many diseases. One is the development of secondary hyperthyroidism due vitamin D deficiency. To date, laboratory quantification methods of serum vitamin D were not well standardized. It could not be established with certainty from which levels of vitamin D certains abnormalities take place, like an elevation of PTH. The present study was aimed at determining below what vitamin D levels we will find abnormally high levels of PTH, carrying out the vitamin D determination in the laboratory with a standardized, reliable technique. Methods: This descriptive, retrospective study was conducted with patients over 18 years in which determinations were made simultaneously with PTH, 25 (OH) vitamin D (25OHD) and which also have normal values of calcium, glomerular filtration rate and phosphorus. For determining vitamin D, standardized electrochemiluminescence method was used with gas chromatography- mass spectrometry method. Using the Stava version 11 statistical program, the 25OHD was calculated where PTH value was above 70 pg/ml with greater sensitivity and specificity. Results: In all, 4,083 patients were included, of whom 2,858 were women (70%) and 1,225 (30%) males. The mean age of the study population was 60.60 years (standard deviation, 15.29). 74% of the population had a serum PTH under 70 pg/ml (normal values) and 26% had a serum PTH higher tan 70 ng/ml. By constructing the ROC curve levels of 25OHD, depending on PTH values below or above 70 pg/ml, the area under the curve was 0.5962 (p<0.0001). The cut having jointly account the sensitivity and specificity that determined vitamin D levels to predict PTH values above 70 pg/ml was 24 ng/ml. Of the patients with normal PTH, 71% presented normal vitamin D values, while patients with elevated PTH (Greater than 70 pg/ml), almost half had a vitamin D below 24 ng / ml, which increased as the PTH percentage was elevated. Conclusions: The 25OHD value that presents better specificity and sensitivity to predict abnormally high PTH is 24 ng/ml, which is higher than the level reported in previous work, (about 18 ng/ml) value. The results of this study, carried out with an appropriately calibrated method, showed that 44.9% of patients with vitamin D values of less than 24 ng/ml PTH had abnormally high levels, with a normal value of calcium and phosphorus and normal renal function. This percentage is less in those individuals between 18 and 40 years (24%) and reaches 49% beyond 60 years. These patients could be treated with vitamin D to prevent possible secondary hyperparathyroidism due to vitamin deficiency. It is noteworthy that the method of determining vitamin D used must be properly standardized with respect to gas chromatography-tandem mass spectrometry method (AU)


Assuntos
Humanos , Masculino , Feminino , Hiperparatireoidismo Secundário/complicações , Hiperparatireoidismo Secundário/diagnóstico , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/diagnóstico , Deficiência de Vitamina D/terapia , Estudos Retrospectivos , Medições Luminescentes/métodos , Dosimetria por Luminescência Estimulada Opticamente/métodos , Testes de Sensibilidade Microbiana/tendências , Sensibilidade e Especificidade , Estudos Transversais/métodos , Estudos Transversais/tendências
2.
Rev. osteoporos. metab. miner. (Internet) ; 8(2): 70-74, abr.-jun. 2016. graf
Artigo em Espanhol | IBECS | ID: ibc-154853

RESUMO

Introducción: La cuantificación de 25(OH) vitamina D total en sangre es el marcador más preciso del estado de vitamina D en un individuo. La técnica patrón-oro para su medición es la cromatografía líquida/ espectrometría de masas en tándem (LC-MS/MS), aunque actualmente los laboratorios clínicos utilizan de rutina técnicas de quimioluminiscencia. El objetivo del estudio fue comparar las concentraciones de 25(OH) vitamina D obtenidas mediante dos métodos automatizados comerciales y estudiar la correlación de dichos métodos con la técnica de referencia LC-MS/MS. Material y método: Se cuantificaron los niveles de 25(OH) vitamina D en 1.000 muestras de suero del laboratorio de Bioquímica de la Fundación Jiménez Díaz mediante 2 métodos automatizados comerciales por detección de quimioluminiscencia: ADVIA CENTAURO® (SIEMENS) y LUMIPULSE® G1200 (FUJIREBIO). Entre todas las muestras analizadas, las 50 más discordantes entre sí se enviaron para ser evaluadas por la técnica de referencia LC-MS/MS. Resultados: Los resultados obtenidos indican que existe una buena correlación entre los dos métodos: CCI=0,923 (0,914-0,932), siendo los valores de LUMIPULSE® G1200 un 10% superiores a los de CENTAURO ®. Con respecto a las 50 muestras seleccionadas, podemos observar que existe una buena correlación entre los dos inmunoensayos con la técnica LC-MS/MS, aunque ambos métodos infraestiman considerablemente los resultados de 25(OH) vitamina D con respecto al patrón-oro. Discusión: Aunque ambas técnicas son adecuadas para su utilización, habría que plantearse si la «epidemia» mundial de hipovitaminosis D se debe a la metodología de análisis utilizada. Esta variabilidad entre inmunoensayos se solucionaría estandarizando las diferentes técnicas comerciales con los materiales de referencia elaborados por el NIST (AU)


Introduction: Quantifying total blood 25 (OH) vitamin D is the most accurate marker of an individual’s vitamin D status. The gold standard technique for measurement is liquid chromatography tandem mass spectrometry (LC-MS/MS), although currently clinical laboratories tend to use chemiluminescence techniques. The objective of this study was to compare 25 (OH) vitamin D concentrations obtained by two commercially-produced automated methods and study the correlation of these methods with the LC-MS/MS reference technique. Material and methods: The 25(OH) vitamin D levels were quantified in 1,000 serum samples from the Jimenez Diaz Biochemistry Foundation Laboratory using 2 automated methods for chemiluminescence detection: ADVIA CENTAURO® (SIEMENS) and LUMIPULSE® G1200 (Fujirebio). Among all the samples tested, the 50 most discordant to each other were sent to be evaluated by LC-MS/MS reference technique. Results: The results indicate that there is good correlation between the two methods: CCI=0.923 (0.914-0.932), with the G1200 LUMIPULSE® values 10% being higher than CENTAURO®. Regarding the 50 samples selected, we can see that there is a good correlation between the two immunoassays with LC-MS/MS, although both methods significantly underestimate 25 (OH) vitamin D results with respect to the gold standard. Discussion: Although both techniques are suitable for use, it is worth considering whether the worldwide vitamin D deficiency epidemic is due to the analysis methodology used. This variability between immunoassays could be solved by standardizing the different commercial techniques in line with NIST produced reference materials (AU)


Assuntos
Humanos , Masculino , Feminino , Medições Luminescentes/métodos , Medições Luminescentes , Vitamina D/uso terapêutico , Cromatografia Líquida/métodos , Cromatografia Líquida , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...